What is PFC?

Time:2018-6-6 9:35:09

Power Factor Correction or PFC is to improve the ratio of apparent power to real power. The power factor is around 0.4~0.6 in non-PFC models. In models with PFC circuit, the power factor can reach above 0.95. The calculation formulas are as follows: Apparent Power=Input Voltage x Input Current (VA), Real Power= Input Voltage x Input Current x Power Factor (W).

From the point of view of environment friendly, the power plant needs to generate a power which is higher than apparent power in order to steadily provide electricity. The real usage of electricity is defined by real power. Assuming the power factor is 0.5, the power plant needs to produce more than 2WVA to satisfy 1W real power usage. On the contrary, if the power factor is 0.95, the power plant only needs to generate more than 1.06VA to provide 1W real power, It will be more effective in energy saving with PFC function.
Active PFC topologies can be divided into single-stage active PFC and two-stage active PFC, the difference is show as in the table below.

 

PFC topology

Advantage

Disadvantage

Limitation

 

Single-stage

 active PFC

 

 

Low cost

 Simple schematic

 High efficiency in 

 small 

 watt application

 

 

Huge Ripple

 complex feedback 

 control

 

 

1.Zero “hold up time”. The output is

    affected by the AC input directly.

 2.Huge ripple current results in lower LED life

    cycle.(drive the LED directly)

 3.Low dynamic responds, easily affected by

    load.

 

 

Two-stage active

 PFC

 

 

High efficiency

 Higher PF

 Easy feedback control

 High adoptive against 

 load condition

 

 

Higher cost

 Complex schematic

 

Suitable for all kinds use